Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
- Category: MELSEC-F Series , Main Unit
-
Operation error of the instruction that handles the present value of a high-speed counter
The present value register of the high-speed counter is the 32-bit register. The applied instruction handling the 32-bit register must be the 32-bit instruct... More Details >>
- No:24907
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , High-Speed Counting
-
The external and mounting dimensions of the FX2N-1PG and the FX3U-1PG are identical. However, the electrical specifications and connectable FX programmable c... More Details >>
- No:24905
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Positioning Control
-
Input filter adjustment when a high-speed counter or the interrupt function is used
When a coil of the high-speed counter or an interrupt pointer is programmed, the programmable controller system adjusts the filter constant of the correspond... More Details >>
- No:24867
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , High-Speed Counter
-
Models of the MELSEC-F series main units
"E" represents AC power supply and "D" represents DC power supply. The alphabets following "E" and "D" represent output types. "S" represents replay output... More Details >>
- No:24776
- Release Date:2019/02/27 15:35
- Category: MELSEC-F Series , Main Unit
-
Use a T-branch repeater module instead of a terminal block. More Details >>
- No:23086
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Identifying disconnected CC-Link stations
Identify disconnected stations using either of the following methods. (1) Select [Diagnostics] -> [CC-Link Diagnostics].from the menu in GX Works2 or G... More Details >>
- No:23053
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:59
- Category: Network related products
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Difference between the CC-Link IE Controller Network and a MELSECNET/H network
The CC-Link IE Controller Network is an improved system that has a higher processing speed and a larger data capacity than the MELSECNET/H network system (PL... More Details >>
- No:22979
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:17
- Category: Network related products
-
How refresh devices for CC-Link remote inputs and outputs are assigned
The refresh device setting of the CC-Link parameter assigns any devices to the I/O numbers greater than those assigned to the modules on the same base unit. ... More Details >>
- No:22968
- Release Date:2018/09/03 17:31
- Category: Network related products