Update timing of LD75 current feed value and machine feed value
The values are updated at the timing described below. - Current feed value: 0.9 ms - Machine feed value: 0.9 ms More Details >>
- No:22748
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
- Category: Engineering Software
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Displaying comments in GX Works2
Select [View] -> [Comment] from the menu to display comments. You can display local comments with the following procedure. (1) Select [Tool] -> [Op... More Details >>
- No:22941
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:58
- Category: Engineering Software
-
Whether or not MC protocol frames can be used after A1SJ71UC24 is replaced with QJ71C24N
The QJ71C24N series modules can be accessed using A-compatible 1C frames, but the following restrictions are imposed. The access is limited to the devices wi... More Details >>
- No:22970
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to install a battery to FX3G/FX3GC series
The FX3U-32BL can be installed to the FX3G/FX3GC series. After installation, select [Battery Mode: Use the battery] on the FX parameter window of GX Develop... More Details >>
- No:22271
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
The Transfer Setup window is displayed in the Navigation window. More Details >>
- No:22579
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Statements of GX Works2 and the scan time
The input method for statements, either "PLC" or "Peripheral", makes a difference. - If "PLC" is set for statements, they are written into the program mem... More Details >>
- No:22856
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:18
- Category: Engineering Software
-
Yes. More Details >>
- No:22998
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Capacity setting of file registers
Set 96K points. (1K point = 1024 points) More Details >>
- No:22610
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series