- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
- Category: Network related products
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Difference between redundant systems and the multiple CPU systems
- Redundant systems A redundant system offers improved system reliability, as it consists of two basic systems, each of which includes a CPU module, powe... More Details >>
- No:22609
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:14
- Category: MELSEC-Q Series
-
The LCPU error code 4116 is displayed when a built-in I/O instruction that is disabled in the parameter setting is executed. Check for the parameter settings... More Details >>
- No:22807
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Clearing the battery error without resetting the CPU module
It is impossible. Battery replacement is essential in clearing the battery error and the power of the programmable controller must be turned off before the... More Details >>
- No:22510
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:27
- Category: MELSEC-Q Series
-
How to display local comments in GX Works2
In the "Reference/Reflection Target for Device Comment" window, switch the "Specify the Reference/Reflection" from "Global" to "Local". More Details >>
- No:22630
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Causes to why SD1286 does not turn on during socket communication of LCPU
Check the following. - Whether the external device specifies the port number of the corresponding connection to the L series CPU. - In the TCP fixed-length... More Details >>
- No:22787
- Release Date:2018/09/03 17:30
- Update:2018/09/22 11:51
- Category: MELSEC-L Series
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Relay life of the MELSEC iQ-R series relay output module (RY10R2)
The mechanical life of the module is 20 million times or longer. The relay life (contact switching life) of the module varies depending on the usage environ... More Details >>
- No:22457
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:12
- Category: MELSEC iQ-R Series