Regarding USB Cable Recommendations
A recommended USB cable is provided. ・MR-J3USBCBL3M(3 m) ・GT09-C30USB-5P(3 m) (manufactured by Mitsubishi Electric System Service Co., Ltd.) More Details >>
- No:40040
- Release Date:2023/08/24 15:45
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding maximum number of connections for MQTT communication function
The MQTT communication function can be used for up to one connection. More Details >>
- No:40055
- Release Date:2023/08/25 08:53
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Email function Attachments
The file formats and file sizes that can be attached by the email function are as follows: ・Attachments: Up to one file ・File formats: Binary, ASCII, CSV... More Details >>
- No:40057
- Release Date:2023/08/25 10:21
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Error code H1968 of FX5-ENET Mail send FB
"The number of characters specified in the input label: i_uBodyLength (number of characters in the body) is different from the number of characters in the bo... More Details >>
- No:44607
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding scan time adjustment for replacing the FX3 Series
You can adjust by setting the constant scan in iQ-F series. Setting procedure: Navigation window > [Parameter] > [Module model name] > [CPU Paramet... More Details >>
- No:44866
- Release Date:2025/03/18 10:24
- Category: MELSEC iQ-F Series , CPU Module
-
External power supply for input(MELSEC-F)
For the MELSEC-F series, only DC power supply type can use an external power supply. More Details >>
- No:22268
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit
-
How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
The duplicated coil error is detected when SET instruction and RST instruction use the same device. More Details >>
- No:22534
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
It includes sample comments for special relay/special register and the intelligent function module. On the menu of GX Works2, select [Edit] -> [Import ... More Details >>
- No:22581
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:12
- Category: MELSEC-Q Series
-
PLC write not possible due to memory overload
If comments cannot be stored in the program memory, write them in the standard ROM or a memory card. Calculate the memory capacity in GX Works2 or GX Develo... More Details >>
- No:22595
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:49
- Category: MELSEC-Q Series