Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
FX series products that support CC-Link Ver.2.0
FX3U-16CCL-M CC-Link master block and the FX3U-64CCL CC-Link interface block supports CC-Link Ver.2.0. Both blocks are dedicated for the FX3 series. More Details >>
- No:25004
- Release Date:2019/04/23 11:11
- Category: MELSEC-F Series , Network/Communication
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control
-
Terminal layout on the output side of the FX3U-16MR/ES
Yes, they are independent common terminals. More Details >>
- No:24955
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Main Unit
-
Ver2.00 or later is applicable. (GX Works2 with Ver. 1.87R or later is applicable.) The version of main units can be checked with the last three digits of t... More Details >>
- No:24922
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Main Unit
-
Number of occupied points of special function devices
Each special function unit/block has 8 occupied points, except for some special function devices. These 8 points do not occupy 8 points of the actual I/O n... More Details >>
- No:24873
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Main Unit
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Using devices assigned as local labels in another program (GX Works2)
No.To read from another program, assign the devices as global labels. More Details >>
- No:22863
- Release Date:2018/09/03 17:30
- Category: Engineering Software