Link data from communication error stations in a CC-Link network
The remote input RX of the master station and the remote input RX and remote output RY of local stations clear/hold the data from an error station according ... More Details >>
- No:23057
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Setting required to skip CC-Link slave station numbers
A CC-Link slave station number can be skipped by assigning the skipped number to a reserved station. A reserved station is counted as one of all the connecte... More Details >>
- No:23029
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MODE switch setting for QJ61BT11N
The MODE switch can set the following modes.- 0 to 4: Online mode- 5 to 9: Line test mode- A to E: Hardware test modeEach mode in ascending order of set valu... More Details >>
- No:23025
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Clearing data in the QJ71C24N's receiving area buffer memory
Receiving data overwrites the buffer memory data. Writing 0 with a program can be performed but is unnecessary as the data is overwritten. More Details >>
- No:23009
- Release Date:2018/09/03 17:31
- Category: Network related products
-
You do not have to change the device numbers for each station number in the initial setting procedure registration window. Example) When the AJ65SBT2B-64A... More Details >>
- No:22949
- Release Date:2018/09/03 17:30
- Update:2018/09/25 11:05
- Category: Engineering Software
-
The conversion speed is 20 microseconds per channel. More Details >>
- No:22826
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
- Category: MELSEC-Q Series