Regarding using the 2nsec Clock Timer
The value of n can be set in SD414, and the range is from K1 to K32767. (Default value: K30) If n=K1, it is a 2-second clock timer with 1 second ON/1 second... More Details >>
- No:40019
- Release Date:2023/08/24 14:29
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49
- Category: MELSEC iQ-F Series , CPU Module
-
The batch setting of PDO mapping sets the default PDO mapping for all device stations that support PDO mapping. *Note that in the batch setting of PDO mappi... More Details >>
- No:44476
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding reuse of GOT connector cable when replacing with FX5 CPU module
The connection cable is GT01-C30R4-8P. The FX5U CPU module does not have an RS422 port, so you will need to add an FX5-422-BD-GOT. More Details >>
- No:44615
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Corrective action when the program size exceeds the capacity
If comments and symbolic information are stored in the program memory, write them in the standard ROM. More Details >>
- No:22560
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Memory allocation for online change
The scan time may be substantially longer. Continue the operation if there is no problem with the longer scan time. More Details >>
- No:22575
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:01
- Category: MELSEC-Q Series
-
Difference between redundant systems and the multiple CPU systems
- Redundant systems A redundant system offers improved system reliability, as it consists of two basic systems, each of which includes a CPU module, powe... More Details >>
- No:22609
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:14
- Category: MELSEC-Q Series
-
Data communications between programmable controllers
Any data can be sent and received if the socket communication function instructions are used. More Details >>
- No:22702
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series