Simultaneous broadcast transmission setting for built-in Ethernet port LCPU
To send simultaneous broadcast using UDP, set the parameters as follows.- Destination IP Address: FF.FF.FF.FFh - Destination Port Number: Other than FFFFh (S... More Details >>
- No:22785
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Measuring temperatures with programmable controllers
The following four models are available for the purpose.- Q64TD- Q64TDV-GH- Q68TD-G-H01- Q68TD-G-H02 More Details >>
- No:22684
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Connecting a DC power supply type extension unit to an AC power supply type main unit
No, they cannot be connected. Connect the units having the same power supply type. More Details >>
- No:25008
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , Main Unit
-
Number of FX3U-ENET-L Ethernet interface blocks that can be connected to the FX3U series
One FX3U-ENET-L can be connected. More Details >>
- No:24939
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Network/Communication
-
Accessing a QnA compatible Ethernet interface module via a router using GX Developer
For GX Developer, a connection via a QnA compatible Ethernet interface module allows communication only within the same segment. Via a router, it is impossib... More Details >>
- No:22845
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Operation during power failure
It stops during execution. More Details >>
- No:22764
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of a commercial SD memory card in L series logging function
Yes. Recommended products are listed in the technical bulletin FA-A-0078. More Details >>
- No:22753
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:25
- Category: MELSEC-L Series
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension