FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Select [Project] -> [Security] -> [User Management] from the menu to display the "User Addition" window.Set "User Name", "Access Level", "Password", an... More Details >>
- No:22871
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Regarding how to Monitor Buffer Memory Values
You can monitor buffer memory values in the Ladder Editor by setting in GX Works3 >Tools >Options > Monitor > Common Item > Monitor Buffer Mem... More Details >>
- No:39324
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the latch settings of data register
It is necessary to set the latch range from the following GX Works3 parameters: [Navigation Window] -> [CPU Parameters] -> [Device/Memory Settings] -&... More Details >>
- No:22329
- Release Date:2018/08/30 13:55
- Update:2024/11/11 13:49
- Category: CPU Module , Engineering Software
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) An intelligent function module is assigned as a... More Details >>
- No:22725
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:02
- Category: MELSEC-L Series
-
How to change the keeping (latched device data) range (FX3G/FX3GC)
The keeping (latched device data) range is fixed and cannot be changed in parameters. (Reference) [When an optional battery is not used] The keeping ran... More Details >>
- No:22260
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:52
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Regarding understanding the differences between Global and Local Labels
Global and local labels have the following differences. Global Label ・This label is available to all programs in the project. ・You can also allocate any d... More Details >>
- No:44622
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
CC-Link slave station's flashing L.ERR LED
If the L.ERR LED flashes at irregular intervals, it may indicate that no terminating resistor has been connected or the communication is instable due to the ... More Details >>
- No:23001
- Release Date:2018/09/03 17:31
- Category: Network related products
-
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sou... More Details >>
- No:22286
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:39
- Category: MELSEC iQ-F Series , CPU Module , I/O Module
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>
- No:22535
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:46
- Category: MELSEC-Q Series