There are three types of parameters in GX Works3; "System parameter", "CPU parameter", and "Module parameter". You can set the following items with each par... More Details >>
- No:22483
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:08
- Category: MELSEC iQ-R Series
-
Regarding the cause of communication error with GX Works3
From the PC's Internet Protocol Version 4 Properties, uncheck "Obtain an IP address automatically" option and set an arbitrary IP adress that does not dupli... More Details >>
- No:22319
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:38
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
How to check the version of the MELSEC-F series
To check the version of the MELSEC-F series, connect GX Works2 (personal computer) or HPP to a programmable controller, and monitor the data in D8001. The l... More Details >>
- No:24772
- Release Date:2019/02/27 15:22
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Error code "2200" in the universal model QCPU
The error code "2200" is "MISSING PARA.". The cause of the error is that a parameter file does not exist in all drives where parameters will be valid.As a re... More Details >>
- No:22614
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It is used for switching between Sink/Source input. For sink input wiring, connect with "24V" terminal and short-circuit the "0V" and "input X***". For sou... More Details >>
- No:22286
- Release Date:2018/08/30 13:55
- Update:2022/12/22 09:39
- Category: MELSEC iQ-F Series , CPU Module , I/O Module
-
M384 to M1535 and D128 to D1099 can be latched. M1536 to M7679, D1100 to D7999, and R0 to R23999 can be used as latch areas by installing an optional batt... More Details >>
- No:24703
- Release Date:2019/02/27 08:59
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>
- No:22662
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:48
- Category: MELSEC-Q Series
-
Regarding how to update the firmware of the FX5 CPU module
FX5U/FX5UC/FX5UJ CPU modules cannot perform firmware update using GX Works3. Use the SD memory card to update the firmware. However, the FX5S CPU module sup... More Details >>
- No:39325
- Release Date:2023/02/14 09:03
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Latch (backup) areas in the data register (D) and extended register (R) of the FX3U/FX3UC series
D200 to D7999 and R0 to R32767 can be latched. D200 to D511 can be set as non-latch areas in parameters. For details on the parameter setting, refer to the... More Details >>
- No:24699
- Release Date:2019/02/27 08:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
GX Works2 update installation procedure
Download the file directly under the C: drive and then install it. More Details >>
- No:22524
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:28
- Category: MELSEC-Q Series