How to write to file registers in Q series
Specify the file in the Write to PLC window and execute writing. More Details >>
- No:22585
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It includes sample comments for special relay/special register and the intelligent function module. On the menu of GX Works2, select [Edit] -> [Import ... More Details >>
- No:22581
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:12
- Category: MELSEC-Q Series
-
Usage of PIDCONT instruction in process CPU
No. More Details >>
- No:22536
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
- Category: MELSEC-Q Series
-
Mounting Q series modules on a MELSEC iQ-R series base unit
You cannot mount Q series modules on a MELSEC iQ-R series base unit. Use an RQ extension base unit (RQ65B, RQ68B, or RQ612B). You cannot mount some modules... More Details >>
- No:22466
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:58
- Category: MELSEC iQ-R Series
-
Relay life of the MELSEC iQ-R series relay output module (RY10R2)
The mechanical life of the module is 20 million times or longer. The relay life (contact switching life) of the module varies depending on the usage environ... More Details >>
- No:22457
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:12
- Category: MELSEC iQ-R Series
-
Regarding understanding EtherNet/IP Settings for FX5-EIP
The EtherNet/IP settings of the FX5-EIP can be set in GX Works3. No additional tools are required. More Details >>
- No:45487
- Release Date:2025/11/12 13:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding protocol mixing in Serial Communication
It is not possible to connect multiple devices with different communication speeds and parities. More Details >>
- No:45480
- Release Date:2025/11/12 13:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding replacement from 128 point type of FX3U
The FX5U CPU module has a lineup of up to 80 point. The following configuration is recommended when replacing the FX3U-128MR/ES. Recommended alternative (1... More Details >>
- No:44617
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module