FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Regarding Selecting a mapping pattern for PDO communication
On the FX5-CCLGN-MS, select "3rd Transmit PDO Mapping" and "3rd Revive PDO Mapping." The 3rd mapping pattern corresponds to the profile position mode (pp), ... More Details >>
- No:44477
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding using the MQTT Communication function in a local environment
Yes, you can use MQTT communication function even in the local network by preparing a personal computer with MQTT broker such as Eclipse Mosquitto installed.... More Details >>
- No:44367
- Release Date:2024/03/27 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the MQTT Communication Function Publish Program
You can't program it with the ladder program alone. To use the MQTT communication and email functions, you must use the module FB and program it. More Details >>
- No:40051
- Release Date:2023/08/25 11:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Data Collection for Device Comments
It is not possible to collect device comments. More Details >>
- No:40030
- Release Date:2023/08/24 14:40
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the FX5S CPU Module Line-up
The line-up of input and output points of the FX5S CPU module is as follows. ・30 points (Input: 16 points, Output: 14 points) ・40 points (Input: 24 points,... More Details >>
- No:39340
- Release Date:2023/02/14 17:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding FX5S CPU module Terminal Block Removal
You can't put it on or take it off. The terminal block of the FX5S CPU module is a non-removable terminal block. More Details >>
- No:39334
- Release Date:2023/02/14 09:10
- Category: MELSEC iQ-F Series , CPU Module
-
Connecting special adapters to the FX3G series
An FX3G-CNV-ADP is required. More Details >>
- No:24977
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Setting for installing a memory cassette
When the programmable controller is powered on after a memory cassette is installed, the memory cassette is automatically recognized. After the memory casset... More Details >>
- No:24974
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit
-
Number of GOTs (GOT1000 series) that can be connected to a FX3U-ENET-L
Up to two GOTs can be connected toa FX3U-ENET-L and MELSOFT connection needs to be set. More Details >>
- No:24933
- Release Date:2019/04/18 14:23
- Category: MELSEC-F Series , Network/Communication
491-500 of Total 1023