Regrading using the Positioning Function with a Relay-Output Type FX5 CPU Module
High-speed pulse I/O module : The FX5-16 ET/ES-H can be added regardless of the output type of the CPU Module, and the positioning function can be used with ... More Details >>
- No:44366
- Release Date:2024/03/27 16:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Interrupt period setting of fixed scan interrupts of MELSEC iQ-R series
You can configure the setting in "Interrupt Setting from Internal Timer" of the CPU parameter. <Interrupt period setting> [Navigation Window]-> ... More Details >>
- No:22490
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:46
- Category: MELSEC iQ-R Series
-
Setting the MELSEC iQ-R series inter-module synchronization function
Set modules in a module configuration diagram with GX Works3 and configure the inter-module synchronization setting. [Navigation Window]-> [Parameter]-... More Details >>
- No:22492
- Release Date:2018/09/03 17:28
- Update:2018/09/20 10:01
- Category: MELSEC iQ-R Series
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
How to read device data and file registers in Q series
Specify the target memory in the Read from PLC window and execute reading. More Details >>
- No:22564
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
- Category: MELSEC-Q Series
-
Use SP.FWRITE instruction to save the data to an SD memory card in CSV format. More Details >>
- No:22727
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series