- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Compatibility between the Japanese and English versions of GX Developer
All the components other than comments in Japanese are supported. Ladder programs and parameters can be used as they are, whether or not they are created usi... More Details >>
- No:22848
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual C++ .NET 2003
MX Component Version 4 does not support Visual C++ .NET 2003. More Details >>
- No:22874
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Difference between QJ61BT11 and QJ61BT11N
QJ61BT11N supports Version 2 (expanded cyclic setting), the setting for refreshing/forced clearing a slave station data when the switch on a programmable con... More Details >>
- No:22964
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:16
- Category: Network related products
-
How to set CC-Link reserved stations
- If the Network Parameter is used Make "Station Information Setting". - If the parameter is set using a dedicated instruction Set the control data of... More Details >>
- No:22996
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:41
- Category: Network related products
-
Transient transmission of the CC-Link IE Controller
Transient transmission is a function that allows communication with programmable controllers in other stations. Communication with programmable controllers i... More Details >>
- No:23016
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Links with a CC-Link local station cannot be made
Check the following points. (1) CC-Link cables have been properly connected. (2) Station numbers and the transmission speed have been correctly set. (3)... More Details >>
- No:23033
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:22
- Category: Network related products
-
Data length for fixed buffer data communications by QJ71E71
The units of send data and receive data are shown below. - Fixed buffer data communications with the "Procedure Exist" control method: Words - Fixed buff... More Details >>
- No:23061
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:17
- Category: Network related products
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
The station number setting is not required for non-protocol communication. More Details >>
- No:24948
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Connection of the FX3GC series and FX3U-ENET-ADP
Since the FX3U-ENET-ADP can be connected directly to the FX3GC series, optional equipment is not required. * When the FX3U-ENET-ADP is used with other spe... More Details >>
- No:24976
- Release Date:2019/04/23 07:20
- Category: MELSEC-F Series , Main Unit , Network/Communication
511-520 of Total 1010