Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Reception data read request signal of QJ71C24N not turn ON
The default receive complete code is CR+LF (0DH, 0AH). The default received data count is 511 words. Hence, at their defaults, Reception data read request si... More Details >>
- No:22984
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:22
- Category: Network related products
-
I cannot convert a circuit created with GX Developer.
When the conversion is executed, online change is automatically executed.When the online change at the upper right section of the setting in "Options" of "To... More Details >>
- No:22958
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Restriction on the use of CPU when branch module and extension module are used
Use L series CPU modules whose first 5 digits of the serial number are "13072" or later. More Details >>
- No:22800
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
TCP retransmission timer setting for built-in Ethernet port LCPU
For the built-in Ethernet port in the L series CPU, the TCP retransmission timer setting is fixed and unchangeable. The retransmission occurs six times. The... More Details >>
- No:22745
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:52
- Category: MELSEC-L Series
-
Hardware setting for using Q series extension base units
You need to set the number of extension base units with the connector for setting the number of extension base units.For details, refer to the following.SH-0... More Details >>
- No:22721
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Compatibility between the A series modules and Q series modules
When an ACPU module is replaced with a QCPU module, programs for the ACPU module can be used by changing the PLC type in GX Developer. However, the programs ... More Details >>
- No:22696
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:21
- Category: MELSEC-Q Series
-
Specifying steps in printing data displayed in the window in GX Works2
GX Works2 Version 1.45X or later supports a print range specifying capability.Set "Start Step" and "End Step" for "Specified Print Range" in the Print window. More Details >>
- No:22695
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
521-530 of Total 1023