Retention of auto tuning setting value for temperature control module
Use the automatic backup setting. While "1: enabled" is set in the CH[] automatic backup setting after auto tuning of PID constants in the buffer memory (Un\... More Details >>
- No:22795
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to obtain connectors used for L series connector type I/O modules
A connector is not included. The connector is obtained by user. A6CON1 (soldering connector, straight out type), A6CON2 (crimp connector, straight out type),... More Details >>
- No:22791
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
SD1282 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1282 (Open completion signal) correspond to the connection numbers 1 to 16. When the open processing is completed, ... More Details >>
- No:22751
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to display the multiple CPU function setting window of MELSEC iQ-R series CPU modules
You can display the setting window in the multiple CPU setting of system parameters. <Multiple CPU setting> [Navigation Window]-> [Parameter]-&g... More Details >>
- No:22484
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:13
- Category: MELSEC iQ-R Series
-
Difference between AJ65SBTB1-16DT1 and AJ65SBTB1-16DT2
Major differences are shown below. - AJ65SBTB1-16DT1 - Rated input current approx. 5 mA - ON voltage/ON current 15 VDC or higher/3.0 mA or higher - O... More Details >>
- No:22972
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:04
- Category: Network related products
-
Function blocks and PLC type change
Yes. Execute conversion/compilation after changing the PLC type. More Details >>
- No:22931
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Clearing the battery error without resetting the CPU module
It is impossible. Battery replacement is essential in clearing the battery error and the power of the programmable controller must be turned off before the... More Details >>
- No:22510
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:27
- Category: MELSEC-Q Series
-
Regarding the default IP address
The default IP address (factory default value) of FX5CPU modules is 192.168.3.250. More Details >>
- No:22290
- Release Date:2018/08/30 13:55
- Update:2022/12/22 08:33
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Protection components of relay contacts
We recommend you to connecta diode for commutation to the DC load, and surge absorber (C-R) to the AC load for the protection of the relay contacts. More Details >>
- No:24999
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Main Unit