FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Simulation function not started
The simulation function utilizes the standard TCP/IP communication provided by Microsoft Corporation. A communication capability of software of another make... More Details >>
- No:22631
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:45
- Category: MELSEC-Q Series
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
L63P compatibility with L series CPU packages
It is possible to remove L61P and use L63P. More Details >>
- No:22742
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Compatibility between GX IEC Developer and GX Developer
GX IEC Developer and GX Developer are different products. They are not compatible. Projects created using GX IEC Developer can neither be opened in GX Develo... More Details >>
- No:22860
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with LJ71E71-100
GX Developer does not support LJ71E71-100. Use GX Works2. More Details >>
- No:22911
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
- Category: Engineering Software
-
Remedies for WDT errors on a MELSECNET/H board
The error code indicates a WDT (watchdog timer) error. It is determined as the cause that the MELSECNET/H driver cannot work due to a computer or OS hang, or... More Details >>
- No:22969
- Release Date:2018/09/03 17:31
- Category: Network related products
-
RS-485 connection between LJ71C24 and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:23048
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
File format that can be saved to a CF card in the FX3U-CF-ADP
CSV file can be saved. More Details >>
- No:24938
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Main Unit , Accessories
531-540 of Total 1023