Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Database function of the MELSEC iQ-R series
You can manage tabular data including product information and production information as a database in a programmable controller. By accessing the database w... More Details >>
- No:22477
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:53
- Category: MELSEC iQ-R Series
-
Versions of LCPU compatible with LJ71E71-100
The L series CPU serial numbers with upper 5 digits of "14112" or later indicate compatibility with LJ71E71-100. More Details >>
- No:22770
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Terminating resistors for RS-485 communication of LJ71C24
The resistance value is 110 ohm, 1/2 W. More Details >>
- No:22999
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:25
- Category: Network related products
-
Difference between networks called CC-Link and those called MELSEC
CC-Link IE, supported by the CC-Link Partner Association, is an open field network standard that integrates networks, from a controller network to field/moti... More Details >>
- No:23013
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Using Ethernet UTP cables for the CC-Link IE Controller
Ethernet UTP cables cannot be used. More Details >>
- No:23062
- Release Date:2018/09/03 17:31
- Category: Network related products
-
You can set the parameters of the FL-net interface module with the data operation of the intelligent function module. For details and operation procedure of... More Details >>
- No:23084
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:19
- Category: Network related products
-
How to change the keeping (latched device data) range (FX3G/FX3GC)
The keeping (latched device data) range is fixed and cannot be changed in parameters. (Reference) [When an optional battery is not used] The keeping ran... More Details >>
- No:22260
- Release Date:2018/08/30 13:48
- Update:2019/02/19 11:52
- Category: MELSEC-F Series , Engineering Software , Main Unit , Accessories
-
Necessities for the execution environment of MX Component
Both the developed software and MX Component must be installed. More Details >>
- No:22557
- Release Date:2018/09/03 17:29
- Update:2018/09/20 15:53
- Category: MELSEC-Q Series
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>
- No:22650
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:47
- Category: MELSEC-Q Series