Opening a Structured Text program in GX Developer
Install the latest version again. Check "Structured Text (ST) Language Programming Function" and install it. More Details >>
- No:22862
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Sample comments for special relays/registers
Files are stored as sample comments when GX Developer is installed. Read a comment from the project data of sample comments to a user project and copy a port... More Details >>
- No:22837
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
- Category: MELSEC-L Series
-
A password can be set. - Use the file password 32 function.- Number of characters: 4 to 32 (alphanumeric and special characters, case-sensitive)- Disabled op... More Details >>
- No:22810
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The built-in I/O functions are standard functions of the L series CPU. Combining these functions flexibly achieves various controls with lower cost, eliminat... More Details >>
- No:22806
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Support for Q series RS-232 cable
Yes. More Details >>
- No:22803
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
RS-232 adapter cable disconnection prevention
Yes. More Details >>
- No:22799
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is that... More Details >>
- No:22797
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Alive check for built-in Ethernet port LCPU
When the protocol is set to TCP, KeepAlive check is performed. (Checking for a response to KeepAlive ACK message) An alive check message is sent five seconds... More Details >>
- No:22782
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series