QnA-compatible 3E frame command (0406) for the built-in Ethernet port QCPU
The built-in Ethernet port QCPU is not compatible with a multiple-block batch read command (0406) of the MC protocol. Executable commands are the following.... More Details >>
- No:22608
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:09
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
Connection status detection between a hub and the built-in Ethernet port of LCPU
The bit 10 of the special register SD1288 provides the connection status to a hub. When the bit 10 of SD1288 is ON, a hub is connected. More Details >>
- No:22759
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The heater disconnection detection function monitors the heater current on the transistor output. If no current flows when the transistor is ON, it is consi... More Details >>
- No:22773
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:58
- Category: MELSEC-L Series
-
Number of records in LCPU logging function
It is the number of data collected before and after a trigger occurrence. More Details >>
- No:22794
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
- Ambient temperature: 25+/-5degrees Celsius with tolerance of +/-0.1% - Ambient temperature: 0 to 55degrees Celsius with tolerance of +/-0.2% (Accuracy f... More Details >>
- No:22811
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:46
- Category: MELSEC-L Series
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Difference between CC-Link reserved stations and invalid stations
- Reserved station Reserved stations are not actually connected to the network (but will be connected in the future) but do not appear as data link error... More Details >>
- No:22993
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:37
- Category: Network related products