Regarding CC-Link IE Field Network Station Type
Local stations can obtain information about all device stations. Intelligent device stations can only obtain information about their own stations. FX5-CCLI... More Details >>
- No:39301
- Release Date:2023/01/12 16:52
- Category: MELSEC iQ-F Series , Network/Communication
-
Not supported. More Details >>
- No:39305
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding communication testing of Certificate Configuration Tool for FX5-ENET
The following are possible causes for communication not being established between the Certificate Configuration Tool for FX5-ENET and FX5-ENET. (1) Connecte... More Details >>
- No:40075
- Release Date:2023/08/25 09:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding cable diversion to FX5-2HC/ES
The cable cannot be used because the connector shape is different, so change the wiring. FX5-2HC/ES is a spring clamp terminal block, and FX3U-2HC is a MIL-... More Details >>
- No:44337
- Release Date:2024/03/20 13:26
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding number of servo amplifiers that can be connected via PDO communication
The maximum number of servo amplifiers connected to the FX5-CCLGN-MS varies according to the number of axes. Example: When connecting a 3-axis servo amplifi... More Details >>
- No:44478
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Memory allocation for online change in GX Works2
The capacity of parameters and programs subtracted from the program capacity for the CPU type in use equals the size of the maximum number of steps. More Details >>
- No:22671
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
SD1282 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1282 (Open completion signal) correspond to the connection numbers 1 to 16. When the open processing is completed, ... More Details >>
- No:22751
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The analog input type (temperature/voltage/current) and offset/gain can be set for each channel. More Details >>
- No:24902
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Analog Control