FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Settings for the FX3U-ENET-ADP
GX Works2 with Ver. 1.87R or later is required. More Details >>
- No:24781
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
When a personal computer (GX Works2) is connected to the RS-232C port of a programmable controller, communications between the personal computer and the prog... More Details >>
- No:24782
- Release Date:2019/02/27 16:10
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Distinguishing the usage of standard counters and high-speed counters
Standard counters offer counting up to 10Hz. For high-speed input signals which exceed 10Hz, use high-speed counters,interruption function, or another proce... More Details >>
- No:24785
- Release Date:2019/02/27 16:31
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
24+ terminal connection of an extension block
For AC power supply type, connect the 24+ terminal of an extension block to the 24+ terminal of a main unit. For DC power supply type, connect the 24+ termi... More Details >>
- No:24786
- Release Date:2019/02/28 09:06
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Writing a program to a memory cassette
A memory cassette has a PROTECT switch to prevent a program from being overwritten in EEPROM and flash ROM. When this switch is on, writing of the program i... More Details >>
- No:24788
- Release Date:2019/02/28 09:07
- Category: MELSEC-F Series , Accessories
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Models from the FX programmable controllers that support the extended register (R)
The following models from the FX3 series support the extended register (R). FX3U/FX3UC series: R0-R32767, FX3G series: R0-R23999 More Details >>
- No:24904
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit
-
Using an expansion board and a special adapter together
In the FX1S/FX1N/FX2N series, only the expansion board for special adapter connection can be used together with the special adapter. In the FX3G series (onl... More Details >>
- No:24906
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Maximum number of personal computers that can be communicated with the FX3U-ENET-L simultaneously
For communications using MELSOFT connection, such as GX Developer, GX Works2, GOT1000, and MX Component, up to two personal computers can be used. In additi... More Details >>
- No:24920
- Release Date:2019/04/17 11:41
- Category: MELSEC-F Series , Network/Communication
571-580 of Total 983