How to change the type of statement in GX Developer
Select [Search/Replace] -> [Replace statement/note type] from the menu and select "Change in PLC". More Details >>
- No:22647
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
It means that in an ambient temperature of 25 degrees Celsius, an error per day falls within the range of "delay of 2.57s" to "advance of 5.27s". "TYP.+2.22... More Details >>
- No:22651
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:53
- Category: MELSEC-Q Series
-
Ladder programs for GX Configurator-FL
When GX Configurator-FL is used, programs for initial settings and cyclic data reading and writing are not needed. More Details >>
- No:22658
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Execution in a multi task environment
The QBF_Open ( ) function or mdOpen ( ) function is required for every task. Do not share the PATH acquired using an Open function with other tasks.Also, exe... More Details >>
- No:22678
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Maximum number of connectable modules to LCPU when it is not extended
Up to 10 modules can be connected in the system as a whole except for the power supply module, CPU module, display unit, RS232C adapter, and END cover. Some ... More Details >>
- No:22775
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series