Assignment of input/output numbers (MELSEC-F series)
Octal numbers are assigned as input/output numbers for the MELSEC-F series. The octal number system uses the digits from 0 to 7 → from 10 to 17 → from 20 to... More Details >>
- No:24868
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Difference between SM0 and SM1
SM0 turns ON when self-diagnostic checks detect an error or when an annunciator turns ON.SM1 turns ON when self-diagnostic checks detect an error. More Details >>
- No:22632
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Regarding the method to check the scan time
The current value of the scan time is stored in the following special devices. Please monitor using GX Works3. ◇Scan information SD520 Current scan time (... More Details >>
- No:22289
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:20
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Meanings of the sink input/source input
The sink input connects to a negative common for 24 V DC. The source input connects to a positive common. The sink input is generally used in Japan and No... More Details >>
- No:22254
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Operation error of the instruction that handles the present value of a high-speed counter
The present value register of the high-speed counter is the 32-bit register. The applied instruction handling the 32-bit register must be the 32-bit instruct... More Details >>
- No:24907
- Release Date:2019/04/15 11:32
- Category: MELSEC-F Series , High-Speed Counting
-
Insufficient memory capacity for sequence programs
It cannot be increased by installing an SRAM card. The size of executable program depends on the program memory size of the CPU. Use another CPU of which p... More Details >>
- No:22578
- Release Date:2018/09/03 17:29
- Update:2018/09/20 17:09
- Category: MELSEC-Q Series
-
Scan time while operation of a programmable controller CPU is being monitored using GX Works2
Scan time displayed on GX Works2 is the maximum scan time of the monitor target programmable controller CPU. To check current scan time, monitor the data in... More Details >>
- No:24779
- Release Date:2019/02/27 15:58
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
The error code "2400" is "FILE SET ERROR".It may be determined as the cause of the error that the file that has been specified by a parameter does not exist.... More Details >>
- No:22703
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Regarding a mismatch found in the monitoring function of GX Works3
Perform "Rebuild All" and initialize the memory before writing to the PLC. "Rebuild All" converts the entire project and "Convert" only coverts the modified... More Details >>
- No:22293
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:31
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
51-60 of Total 1023