Regarding checking latch settings
You can find it in the Advanced Settings section of GX Works3. Use the following procedure to display the Device (High Speed) settings. From the GX Wor... More Details >>
- No:44364
- Release Date:2024/03/27 16:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding compatible version of CANopen communication function for PDO communication
It is necessary to use the following CPU module, FX5-CCLGN-MS, GX Works3 versions. FX5-CCLGN-MS・・・1.020 or later FX5U/FX5UC CPU module ・・・1.260 or later ... More Details >>
- No:44473
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
How to display the multiple CPU function setting window of MELSEC iQ-R series CPU modules
You can display the setting window in the multiple CPU setting of system parameters. <Multiple CPU setting> [Navigation Window]-> [Parameter]-&g... More Details >>
- No:22484
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:13
- Category: MELSEC iQ-R Series
-
Replacing a device in GX Developer
Select [Tool] -> [Options] from the menu of GX Developer and open <<Program common>> tab.Then select "Don't write to PLC" in "After conversion... More Details >>
- No:22565
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
USB cable type for CPU modules
It is type B. More Details >>
- No:22622
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Versions of the QJ71C24N modules compatible with QnUDVCPU
The QJ71C24N series modules with serial numbers with upper 5 digits of "10042" or later indicate compatibility with QnUDVCPU. More Details >>
- No:22628
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>
- No:22640
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:39
- Category: MELSEC-Q Series
-
The error code "2400" is "FILE SET ERROR". This error may be caused when the file specified with a parameter does not exist. The individual information param... More Details >>
- No:22729
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Storing the data logging setting to an SD memory card in LCPU
In the write logging setting, choose [Online] and [Write Logging Setting], and set the target memory to SD memory card. More Details >>
- No:22758
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SD1284 of LCPU with built-in Ethernet port
The bits 0 to F of the special register SD1284 (Open request signal) correspond to the connection numbers 1 to 16. When the open request is sent, the corresp... More Details >>
- No:22784
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series