FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Buffer memory addresses of CC-Link modules
If the remote net Ver.1 mode is used, each station number is given fixed buffer memory addresses.If the remote net Ver.2 mode is used, different buffer memor... More Details >>
- No:22992
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Regarding the COM terminal of the multiple input module
Yes, it's connected internally. More Details >>
- No:39318
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , Analog
-
Digit specification for bit devices in ST language with GX Works3
For a label where digits are to be specified, set a bit type array as its data type. The following shows an example of when a global label is used. - Globa... More Details >>
- No:22455
- Release Date:2018/09/03 17:28
- Update:2018/09/18 15:01
- Category: MELSEC iQ-R Series
-
Using Structured Text in GX Works2 simple projects
Select "Use Label" in the New Project window. More Details >>
- No:22562
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Alive check for built-in Ethernet port LCPU
When the protocol is set to TCP, KeepAlive check is performed. (Checking for a response to KeepAlive ACK message) An alive check message is sent five seconds... More Details >>
- No:22782
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Opening function block and Structured Text projects in GX Works2
The project can be read by selecting "Open other project" in GX Works2. - Function names for the GX Developer's Structured Text are different from those of ... More Details >>
- No:22864
- Release Date:2018/09/03 17:30
- Update:2018/09/22 14:28
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Basic 6.0
MX Component Version 4 does not support Visual Basic 6.0. More Details >>
- No:22884
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Terminating resistors for CC-Link communication
There are two types of terminating resistors for CC-Link communication. Both two types are packaged with a CC-Link master/local module. (1) 110 ohm, 1/2W (B... More Details >>
- No:22963
- Release Date:2018/09/03 17:31
- Update:2018/09/26 14:47
- Category: Network related products
-
Models from the FX programmable controllers that support the extended register (R)
The following models from the FX3 series support the extended register (R). FX3U/FX3UC series: R0-R32767, FX3G series: R0-R23999 More Details >>
- No:24904
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Main Unit