FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
"[ ]" in the CC-Link remote I/O modules' model name "AJ65[ ]BT" represents as follows: - None: Standard type - S: Compact type - F: Low profile waterpro... More Details >>
- No:22974
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:12
- Category: Network related products
-
Index modification in function blocks
Index modification cannot be used for labels. To set index modification, use actual devices as the target devices. More Details >>
- No:22930
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
The number of FB definitions created in a project has no limitation. More Details >>
- No:22900
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Limit on the display of data collected in GX LogViewer to 32 values
GX LogViewer is made to a specification that allows a single trend window to display a maximum of 32 graphs. When there are more than 32 logging data values,... More Details >>
- No:22889
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with QnUDVCPU
GX Developer does not support QnUDVCPU. Please use GX Works2 instead. More Details >>
- No:22885
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Precautions for insertion and removal of SD memory card
Turn off the SD memory card switch and check that the LED indicator is off before insertion or removal of an SD memory card. More Details >>
- No:22818
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is that... More Details >>
- No:22797
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Precautions for use of SD memory card
Yes. Note that SD memory cards are formatted at the factory. If an SD memory card needs to be reformatted, format it using the CPU module. More Details >>
- No:22779
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series