FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Ethernet cables for the CC-Link IE Field Network
General-purpose Ethernet cables that meet the 1000BASE-T standard (category 5e or higher) can be used. We recommend double shielded cables. Recommended pro... More Details >>
- No:22989
- Release Date:2018/09/03 17:31
- Update:2019/06/27 15:47
- Category: Network related products
-
Difference between the CC-Link IE Controller Network and a MELSECNET/H network
The CC-Link IE Controller Network is an improved system that has a higher processing speed and a larger data capacity than the MELSECNET/H network system (PL... More Details >>
- No:22979
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:17
- Category: Network related products
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
- Category: Network related products
-
Terminating resistors for RS-422 communication of QJ71C24N
The resistance value is 330 ohm, 1/4 W. More Details >>
- No:22965
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:33
- Category: Network related products
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
I cannot open a project file of PX Developer.
When the total number of characters in the drive/path and project name exceeds 149 one-byte characters (74 two-byte characters), the message "The drive path ... More Details >>
- No:22947
- Release Date:2018/09/03 17:30
- Update:2018/09/25 10:58
- Category: Engineering Software
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
- Category: Engineering Software
-
Duplicated coil errors that can be checked with GX Works2
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22932
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Behavior of special relay in offline simulation
The constant scan initial value of GX Simulator is 100 ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set the consta... More Details >>
- No:22922
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:39
- Category: Engineering Software
-
Dragging and dropping function blocks in a structured project
Function blocks can be dragged and dropped into the program main body of the program block, and become available in the program. More Details >>
- No:22910
- Release Date:2018/09/03 17:30
- Category: Engineering Software
641-650 of Total 983