Regarding Input Response Frequency Difference between FX5-2HC/ES and Conventional Model (FX3U-2HC)
The input response frequencies of the FX5-2HC/ES and FX3U-2HC differ as shown below. FX5-2HC/ES・・・2MHz FX3U-2HC・・・200kHz More Details >>
- No:44340
- Release Date:2024/03/20 13:31
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding the Number of Sending Addresses for Email function
The FX5-ENET module parameter of GX Works3 can send up to 10 messages and the module FB can send up to 256 characters at a time. By entering multiple email ... More Details >>
- No:40052
- Release Date:2023/08/25 10:23
- Category: MELSEC iQ-F Series , Network/Communication
-
Output frequency of the FX3U-1PG pulse output block
It is from 1 Hz to 200 kHz. More Details >>
- No:24981
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Positioning Control
-
Using a fixed latched (battery backed) type device as a general type device
Clear the required area with the ZRST instruction by using the initial pulse when the programmable controller is set to RUN. To clear all the latched type de... More Details >>
- No:24925
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Main Unit
-
The analog input type (temperature/voltage/current) and offset/gain can be set for each channel. More Details >>
- No:24902
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Analog Control
-
How to check errors in a CC-Link master station
When an error has occurred in the master station (including the standby master station), the data link control cannot be performed, and you cannot check erro... More Details >>
- No:23078
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Link register assignments in MELSECNET/10 networks
For any type of MELSECNET network (II, /10, and H), B and W devices with the same number cannot be used for multiple stations as write areas. Following th... More Details >>
- No:22971
- Release Date:2018/09/03 17:31
- Update:2018/09/25 13:24
- Category: Network related products
-
Can I open a program created with GX Works2 in GX Developer?
You cannot open a program in the file format for GX Works2. When saving a project with GX Works2, save it in the format for GX Developer.(This is possible on... More Details >>
- No:22956
- Release Date:2018/09/03 17:31
- Category: Engineering Software
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
- Category: MELSEC-Q Series
-
Data communications between programmable controllers
Any data can be sent and received if the socket communication function instructions are used. More Details >>
- No:22702
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series