Maximum number of connectable modules to LCPU when it is not extended
Up to 10 modules can be connected in the system as a whole except for the power supply module, CPU module, display unit, RS232C adapter, and END cover. Some ... More Details >>
- No:22775
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Execution of the SOCRMODE instruction in the same connection during socket communication of LCPU
It can be executed for the same connection number. When data exist in the socket communication receive data area and the SOCRMODE instruction is executed, va... More Details >>
- No:22771
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Versions of LCPU compatible with LJ71E71-100
The L series CPU serial numbers with upper 5 digits of "14112" or later indicate compatibility with LJ71E71-100. More Details >>
- No:22770
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of a commercial SD memory card in L series logging function
Yes. Recommended products are listed in the technical bulletin FA-A-0078. More Details >>
- No:22753
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:25
- Category: MELSEC-L Series
-
The number of LCPU extension blocks
(1) The number of modules to be connected- Main block: up to 10 modules- Extension block: up to 11 modules(2) The number of extension blocks- L02CPU, L02CPU-... More Details >>
- No:22750
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Communication between CPUs via built-in Ethernet port in LCPU
The following communication methods are available between the built-in Ethernet ports in the L series CPUs.- Simple PLC communication function- Socket commun... More Details >>
- No:22746
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Use of an A-compatible 1E frame for the built-in Ethernet port of LCPU
The built-in Ethernet port in the L series is compatible only with a QnA-compatible 3E frame of the MC protocol. An A-compatible 1E frame is not supported. More Details >>
- No:22731
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
You can use the output change upper limit value and the MV upper/lower limit limiter, the functions common to each PID control tag. Set the following parame... More Details >>
- No:22724
- Release Date:2018/09/03 17:29
- Update:2018/09/26 16:40
- Category: MELSEC-Q Series
-
Programing example of heating/cooling control
The following shows an example of heating/cooling control using split control. * For details, refer to the "Programmable Controllers MELSEC PROC... More Details >>
- No:22719
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:43
- Category: MELSEC-Q Series
-
SD memory cards used for Q24DHCCPU-V
Mitsubishi Electric's SD memory cards, which can be installed into Q24DHCCPU-V, are shown below. - NZ1MEM-2GBSD (memory capacity: 2Gbytes) - NZ1MEM-4GBSD (... More Details >>
- No:22711
- Release Date:2018/09/03 17:29
- Update:2018/09/22 08:58
- Category: MELSEC-Q Series
671-680 of Total 983