Current value of the battery voltage in the FX3U/FX3UC series
The current value of the battery voltage is stored in the special data register D8005 (battery voltage). More Details >>
- No:24942
- Release Date:2019/04/18 14:25
- Category: MELSEC-F Series , Main Unit
-
The main units with Ver.2.00 or later can read and write programs of the FX3 series connected to the intelligent device station and can monitor devices. (GX... More Details >>
- No:24950
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Types of the ports built in the FX programmable controllers
There are RS422 × 1ch for the FX1S/FX1N/FX1NC/FX2N/FX2NC/FX3U/FX3UC series and RS422 × 1ch and USB × 1ch for the FX3G/FX3GC series. More Details >>
- No:24971
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit
-
Triac output type main units in the FX3 series
The FX3U-32MS/ES and FX3U-64MS/ES are triac output type. More Details >>
- No:24980
- Release Date:2019/04/23 07:21
- Category: MELSEC-F Series , Main Unit
-
Regarding connection through a MODBUS/TCP Gateway
Communication is possible with simple CPU communication function of FX5CPU, FX5-ENET, FX5-ENET/IP modules. ※FX5U and FX5UC CPU modules with firmware version... More Details >>
- No:39343
- Release Date:2023/01/12 17:05
- Update:2023/06/23 11:13
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the communication execution status output device for ADPRW instructions
It does not turn OFF automatically. Use the RST command in the program to turn it OFF. More Details >>
- No:39349
- Release Date:2023/02/15 10:07
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding configuring of Data Logging
The CPU module logging feature is accessed from the CPU module logging configuration tool. If the tool is installed, launch it from GX Works3 Tools > Logg... More Details >>
- No:44613
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding support for the FX5-EIP Auto refresh function
The Auto refresh function is supported. More Details >>
- No:45488
- Release Date:2025/11/12 13:55
- Category: MELSEC iQ-F Series , Network/Communication
-
Duplicated coil errors that can be checked with GX Works3
When an SET instruction and RST instruction use a single device, no duplicated coil error is detected. More Details >>
- No:22456
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:33
- Category: MELSEC iQ-R Series