FAQ within [ Programmable Controllers MELSEC ]
-
How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
MX Component's compatibility with Windows7 Embedded
MX Component does not support Windows7 Embedded. More Details >>
- No:22698
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Remedy for the division-related operation error
The operation error occurs when the divisor is 0.Create a program in which a comparison operation instruction or another method executes a division instructi... More Details >>
- No:22691
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Speeds of access to file registers
If file registers are registered in the standard RAM and "R" is specified by an instruction, the processing time is the same as is the case with the internal... More Details >>
- No:22688
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Intelligent function module settings in GX Works2
Modules do not need setting in GX Works2 if not selectable from "Module Selection" in the "New Module" window for intelligent function module settings. More Details >>
- No:22685
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to check errors with error codes of QD75
Errors can be checked with the following error detection signals and buffer memory areas corresponding to each axis.- Axis 1 Error detection X8 Buffer memor... More Details >>
- No:22667
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Production of Q61P-A1 and Q61P-A2
They have gone out of production. However, Q61P, a succeeding model, can be used in the same way. More Details >>
- No:22655
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
COMMENT to disappear after a PLC type change
Copy the COMMENT into the MAIN of comments by program before changing the PLC type.The basic model QCPU cannot deal with common comments. More Details >>
- No:22625
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
CF cards supported by the high speed data logger module
For applicable CF cards, refer to the latest version of the following manual.- High Speed Data Logger Module User's Manual- SH-080818ENG- 2.3 Connection Syst... More Details >>
- No:22607
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Reading and writing bits/words using the FL-net (OPCN-2) interface module
The parameters and auto refresh settings for the FL-net (OPCN-2) interface module cannot be made using the Network Parameter items in GX Developer.Set those ... More Details >>
- No:22597
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series