Cable length to connect to built-in Ethernet port in LCPU
The maximum length between a hub and a node is 100 m. The max. length connectable to a hub is 200m.When repeater hubs are used in cascade connection, the max... More Details >>
- No:22781
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Number of records in LCPU logging function
It is the number of data collected before and after a trigger occurrence. More Details >>
- No:22794
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Removal of SD memory card during logging in L series
An error will occur in CPU. More Details >>
- No:22812
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
They can be used simultaneously when I/O signals are not overlapped. The overlap of signals are checked automatically when a user select functions in the bui... More Details >>
- No:22816
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
An error occurs and CPU will stop. Install the END cover and reset the CPU module. More Details >>
- No:22817
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Difference in specifications between CC-Link versions
Ver.1.10 is a standard where CC-Link station-to-station cable length restriction in Ver. 1.00 has been removed, and the length of all station-to-station cabl... More Details >>
- No:22975
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to set CC-Link reserved stations
- If the Network Parameter is used Make "Station Information Setting". - If the parameter is set using a dedicated instruction Set the control data of... More Details >>
- No:22996
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:41
- Category: Network related products
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Executing the QJ71C24N's pre-defined protocol support function
Executing the CPRTCL instruction (dedicated instruction) executes a specified protocol. More Details >>
- No:23004
- Release Date:2018/09/03 17:31
- Category: Network related products