FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Regarding initialization procedure
From GXWorks3, use [Online] -[CPU Memory Operation] to initialize. How to check the IP address is as follows. They are stored in special registers SD8492 a... More Details >>
- No:45481
- Release Date:2025/11/12 13:54
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding checking the input/output data of the FX5-EIP
This can be checked by monitoring the corresponding buffer memory from the Register to Intelligent Function Module Monitor. From [Parameter] - [Module Infor... More Details >>
- No:45490
- Release Date:2025/05/08 09:08
- Update:2025/10/31 15:18
- Category: MELSEC iQ-F Series , Network/Communication
-
The FX3 intelligent function modules cannot be selected from the Element selection window because it does not correspond to the parameter setting of GX Works... More Details >>
- No:22304
- Release Date:2018/08/30 13:55
- Update:2024/08/19 09:50
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the number of available channels of the built-in high speeed counters.
The high-speed counter supports 1-phase 1-input, 1-phase 2-input, 2-phase 2-input. The built-in counter in the CPU module can input up to 8ch. However,... More Details >>
- No:22310
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:42
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding the frequency of high-speed counters
The maximum frequency of the FX5U/FX5UC CPU module is 200kHz and the maximum frequency of the FX5S/FX5UJ CPU module is 100 kHz. More Details >>
- No:22312
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:18
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
How to display the network parameter setting window with GX Works3
"Network Parameter" in GX Works2 is "Module Parameter" of a "network module" in GX Works3. Click the items in the following order to display the setting win... More Details >>
- No:22485
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:55
- Category: MELSEC iQ-R Series
-
This occurs when the specified memory does not have consecutive free space in it. In this case, delete unnecessary files or arrange the PLC memory. Select ... More Details >>
- No:22604
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:03
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
- Category: MELSEC-L Series
-
Checking the amount of free space of the memory in GX Developer/GX Works2
Select [Tool] -> [Confirm Memory Size] to check the amount. More Details >>
- No:22851
- Release Date:2018/09/03 17:30
- Category: Engineering Software
701-710 of Total 1023