Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding parameter setting for FX5-CCL-MS
It is possible to set the basic/application settings in a program by selecting the parameter setting method to "Program." Even if set by "program" is select... More Details >>
- No:39367
- Release Date:2023/01/12 17:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Cloud recommended Services
AWS IoT Core and Azure IoT Hub are recommended. *AWS IoTCore is a registered trademark of Amazon Web Services, Inc. *Azure IoT Hub is a registered ... More Details >>
- No:40036
- Release Date:2023/08/24 15:42
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding setting up encrypted communication (TLS) for FX5-ENET
In GX Works3, set the FX5-ENET module parameters from Basic Settings - External Device Configuration Settings. In the "Ethernet Configuration" screen, selec... More Details >>
- No:40050
- Release Date:2023/08/25 08:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding how to change the averaging processing of FX5-4AD-ADP programmatically
It is possible to change the number of counts for count averaging in a program. Set the module parameter Basic settings to "Set A/D conversion method" to Di... More Details >>
- No:44618
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , Analog
-
Regarding understanding the differences between Global and Local Labels
Global and local labels have the following differences. Global Label ・This label is available to all programs in the project. ・You can also allocate any d... More Details >>
- No:44622
- Release Date:2024/11/28 16:13
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding number of CC-Link IE field network Basic connections
When the FX5 CPU Module is used as the master station, the maximum number of devices connected to 1 network is 16. The following firmware versions are requi... More Details >>
- No:44652
- Release Date:2025/03/18 10:22
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Communication data code of the MC protocol for the built-in Ethernet port in LCPU
The communication data code is selectable by the communication data code setting in [Parameter] -> [PLC Parameter] -> [Built-in Ethernet Port Setting]. More Details >>
- No:22735
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:22
- Category: MELSEC-L Series