FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Number of remote registers assigned to a remote I/O station
For "Remote Net(Ver.2 Mode)", the number of remote I/O's remote registers (RWw, RWr) is "0 Point". More Details >>
- No:22973
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Reference manuals for programming for FX programmable controllers in ST language
The following shows the manuals for programming in ST language. - GX Works2 Beginner's Manual (Structured Project) - GX Works2 Version 1 Operating Manual... More Details >>
- No:22959
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:16
- Category: Engineering Software
-
Displaying the next page in the Print Preview window
It is only possible to preview the first page to verify the print size and form. More Details >>
- No:22924
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Specifying the number of digits in the Structured Text
For actual bit devices, the number of digits can be specified. For labels, the number of digits cannot be specified. More Details >>
- No:22891
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
CW Workbench can be purchased from Mitsubishi Electric. We also accept license applications. More Details >>
- No:22880
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
I/O assignment for additional modules connected to LCPU
In L02CPU(-P), the start I/O number of the additional module begins from 10H. In L26CPU-(P)BT, the number begins from 30H. More Details >>
- No:22808
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
GX Developer Version 8.89T or later is supported.There are restrictions in some functions. For the details, refer to "Precautions on L Series Modules" in ... More Details >>
- No:22792
- Release Date:2018/09/03 17:30
- Update:2018/10/03 16:26
- Category: MELSEC-L Series
-
The heater disconnection detection function monitors the heater current on the transistor output. If no current flows when the transistor is ON, it is consi... More Details >>
- No:22773
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:58
- Category: MELSEC-L Series
-
Behavior of sequence program in event of momentary power failure in LCPU
(1) When it happened no longer than the allowable momentary power failure time. The module records an error log and suspends the operation processing. Ho... More Details >>
- No:22756
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:43
- Category: MELSEC-L Series
721-730 of Total 1023