FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Communication between a CC-Link master station and local stations
There are two modes of transient transmission, cyclic transmission and transient transmission, for the communication between a master station and a local sta... More Details >>
- No:23006
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:53
- Category: Network related products
-
Regarding the difference between digital output values and digital operation values
The digital output value is a digital value obtained by performing sampling processing or various average processing on the A/D converted digital value. Dig... More Details >>
- No:39307
- Release Date:2023/02/13 16:43
- Category: MELSEC iQ-F Series , CPU Module , Analog
-
Differences in the specifications between the programmable controllers used in Japan and overseas.
The input signal forms are different. All the programmable controllers for the domestic market other than the FX3G/FX3U series are the sink input. The progra... More Details >>
- No:24913
- Release Date:2019/04/17 11:39
- Category: MELSEC-F Series , Main Unit
-
Difference between Q61P and Q64PN
There are differences in 5 VDC rated output current and in 5 VDC overcurrent protection.The difference in 5 VDC rated output current is as follows.- Q61P: 6 ... More Details >>
- No:22518
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Heat generation of Q61P power supply module
Since the conversion efficiency of the power supply module is approximately 70%, and 30% of the output power is dissipated as heat, the power consumption is ... More Details >>
- No:22529
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Languages supported by structured projects
Yes. More Details >>
- No:22855
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Unit of the receive data length used by the QJ71C24N series pre-defined protocol support function
The receive data length of the variable is specified in bytes. More Details >>
- No:23037
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Regarding CC-Link IE Field Network Basic Communication Between FX5 CPU Modules
Since the FX5 CPU modules only support the master function, CC-Link IE Field Network Basic communication between FX5 CPU modules is not possible. More Details >>
- No:39297
- Release Date:2023/02/13 16:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
All input COM terminals send the same signal because all the terminals are internally connected. To turn on the input, the extension unit must be connected ... More Details >>
- No:22274
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Connect with a straight cable using a hub. For more details, refer to the following manual. - FL-net (OPCN-2) Interface Module User's Manual More Details >>
- No:22574
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:55
- Category: MELSEC-Q Series
731-740 of Total 1023