FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Regarding connector conversion module differences
The FX5-CNV-IF is an additional cable type. ・FX5U/FX5UJ CPU Modules are supported. ・Used to connect an extension connector type module to an extension ca... More Details >>
- No:44351
- Release Date:2024/03/27 15:45
- Category: MELSEC iQ-F Series , CPU Module
-
Periodic replacement is recommended. For example, standard life of FX3U-32BL is 5 years (at ambient temperature of 25). The life of the battery changes wit... More Details >>
- No:22262
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53
- Category: MELSEC iQ-F Series , Network/Communication
-
The setting in Latch (1) can be cleared by latch clear operation. The setting in Latch (2) cannot be cleared by latch clear operation. More Details >>
- No:22567
- Release Date:2018/09/03 17:29
- Update:2018/09/20 16:48
- Category: MELSEC-Q Series
-
This occurs when the specified memory does not have consecutive free space in it. In this case, delete unnecessary files or arrange the PLC memory. Select ... More Details >>
- No:22604
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:03
- Category: MELSEC-Q Series
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is that... More Details >>
- No:22797
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
- Category: Engineering Software
741-750 of Total 1023