Connection of expansion boards and a memory cassette to the FX3G series main unit
They can be used together. * 14/24-point type FX3G series main unit ・ An expansion board can be connected to BD1 (1st position) and a memory cassette can b... More Details >>
- No:24952
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit
-
Types of the ports built in the FX programmable controllers
There are RS422 × 1ch for the FX1S/FX1N/FX1NC/FX2N/FX2NC/FX3U/FX3UC series and RS422 × 1ch and USB × 1ch for the FX3G/FX3GC series. More Details >>
- No:24971
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Main Unit
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding protocol creation of Predefined Protocol Support Function
You can not create a protocol for the other device. More Details >>
- No:39293
- Release Date:2023/02/13 15:38
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding Data Logging File Storage Format
It's possible. For the firmware and software versions of the corresponding CPU units, refer to the respective manuals. More Details >>
- No:39308
- Release Date:2023/02/13 16:44
- Update:2023/02/14 09:01
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding number of input/output points when adding safety extension module
It will. It is treated the same as an intelligent module, so it occupies 8 I/O points. The safety input expansion module FX5-SF-8DI4 does not occupy the numb... More Details >>
- No:39314
- Release Date:2023/01/12 16:54
- Category: MELSEC iQ-F Series , CPU Module , Safety Control
-
Regarding Gray code conversion
There is. Please use the GBIN instruction. More Details >>
- No:39322
- Release Date:2023/02/14 09:02
- Category: MELSEC iQ-F Series , CPU Module
761-770 of Total 983