FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Connection of a totem pole output encoder
The totem pole output encoder cannot be connected to the FX2NC-1HC/FX2N-1HC/ FX3U-2HC. The connectable encoders are as follows. ・ Open collector output typ... More Details >>
- No:25010
- Release Date:2019/04/23 11:12
- Category: MELSEC-F Series , High-Speed Counting
-
Regarding FX5 CPU Module clock settings
There are three types of configuration: GX Works3, special devices (SM/SD), and instructions. ・How to Configure in GX Works3 (1) In GX Works3, select On... More Details >>
- No:44365
- Release Date:2024/03/27 17:01
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
I/O structure error in the MELSEC-F
When an unimplemented input (X) or output (Y) number is used in a program, M8060 turns on. The first to third digits of the numericalvalue stored in D8060 i... More Details >>
- No:22284
- Release Date:2018/08/30 13:48
- Update:2019/02/18 15:17
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
From the following menu of GX Works3: [Diagnostics]→[Module Diagnostics(CPU Diagnostics)] the event history function can be found. The event history can dis... More Details >>
- No:22305
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the connection configuration of FX5-CCL-MS
Connection is not allowed. For FX5-CCL-MS, only remote I/O stations, remote device stations andintelligent device stationscan be connected. More Details >>
- No:22316
- Release Date:2018/08/30 13:55
- Update:2023/07/03 17:19
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the system configuration of FX5-CCL-MS with FX5 CPU module
A total of two FX5-CCL-MS (CC-Link system master/intelligent device) can be connected: one as a master station and one as an intelligent device station. More Details >>
- No:22318
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:50
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding model name of CC-Link cables
The CC‐Link cables are being produced by various manufacturers, and no specific cable model is recommended. Please use a cable certified by the CC-Link Asso... More Details >>
- No:22330
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:53
- Category: MELSEC iQ-F Series , Network/Communication
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
- Category: MELSEC iQ-R Series
771-780 of Total 976