Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
The communication format can be set in the communication setting of a sequence program or "PLC Parameter setting" using GX Developer. To avoid setting troub... More Details >>
- No:24929
- Release Date:2019/04/17 11:42
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
The station number setting is not required for non-protocol communication. More Details >>
- No:24948
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Connection of expansion boards and a memory cassette to the FX3G series main unit
They can be used together. * 14/24-point type FX3G series main unit ・ An expansion board can be connected to BD1 (1st position) and a memory cassette can b... More Details >>
- No:24952
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit
-
Instruction execution complete flag
When a flag contact is not programmed directly under the instruction to be checked, the flag may be turned off depending on the execution status of another i... More Details >>
- No:24988
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Main Unit
-
Regarding the line tracing function
It is not supported. More Details >>
- No:39323
- Release Date:2023/02/14 09:01
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module
-
CC-Link IE field When a network such as Network Basic is interrupted, the CPU module does not stop and continues to run. When the CC-Link IE Field Network i... More Details >>
- No:44611
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Yes, it is possible. Please consider functions such as Simple CPU communication or socket communication. More Details >>
- No:22294
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:00
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding changing the current value of the high-speed counter.
To rewrite the current value, arbitrary values can be written using the DHCMOV instruction. (Example) Set the current value of the high-speed counter ch1 ... More Details >>
- No:22303
- Release Date:2018/08/30 13:55
- Update:2023/02/06 17:05
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter