FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Maximum number of connectable modules to LCPU when it is not extended
Up to 10 modules can be connected in the system as a whole except for the power supply module, CPU module, display unit, RS232C adapter, and END cover. Some ... More Details >>
- No:22775
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Versions of built-in Ethernet port LCPU compatible with SNTP function
The initial version and subsequent versions of L series CPU support the SNTP function. More Details >>
- No:22769
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Update timing of LD75 current feed value and machine feed value
The values are updated at the timing described below. - Current feed value: 0.9 ms - Machine feed value: 0.9 ms More Details >>
- No:22748
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
There are no settings for deleting the network number and PC number. More Details >>
- No:22708
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Setting of "Target MODBUS(R) device head number"
Set "(Last five digits of actual device number) - 1" for the Target MODBUS(R) device head number.Example) For the holding register 400018, set "17". More Details >>
- No:22682
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The corresponding operation depends on the counter type selected. (1) If "Linear Counter" is selected If the present counter value exceeds the upper limi... More Details >>
- No:22624
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:32
- Category: MELSEC-Q Series
-
USB cable type for CPU modules
It is type B. More Details >>
- No:22622
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Procedure for developing programs
It is necessary to install a development environment (Tornado or Wind River Workbench) and set parameters using the Setting/monitoring tools for the C Cont... More Details >>
- No:22600
- Release Date:2018/09/03 17:29
- Update:2018/09/21 18:52
- Category: MELSEC-Q Series
-
"No administrator authority" warning displayed in MX Component
The user account control (UAC) setting needs to be changed.For more details, refer to Appendix 8.2 of the following manual.- MX Component Version 3 Operating... More Details >>
- No:22590
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
781-790 of Total 1023