Regarding FX5U/FX5UC CPU Module Built-in functions
The functions supported only by the FX5U/FX5UC CPU Modules are listed below. ・Predefined Protocol Support Function For Positioning function ・Optional batte... More Details >>
- No:40046
- Release Date:2023/08/24 16:14
- Update:2024/11/11 14:29
- Category: MELSEC iQ-F Series , CPU Module
-
The following points are different for the iQ-F series. ・Error History If the FX5 CPU Module is turned off, the error history is cleared. ・Setting detail... More Details >>
- No:44335
- Release Date:2024/03/20 13:21
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding number of occupied I/O points of intelligent function module
The number of occupied input/output points per module is 8. (Excluding some models) Occupied I/O points: Since actual occupied I/O points cannot be assigned... More Details >>
- No:44612
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , CPU Module
-
Corrective action when the program size exceeds the capacity
If comments and symbolic information are stored in the program memory, write them in the standard ROM. More Details >>
- No:22560
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to write comments of GX Works2 into the standard ROM
Switch the Target Memory to "Standard ROM" in the "Write to PLC" window. More Details >>
- No:22611
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Error code "2200" in the universal model QCPU
The error code "2200" is "MISSING PARA.". The cause of the error is that a parameter file does not exist in all drives where parameters will be valid.As a re... More Details >>
- No:22614
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
QCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices. - Protocol: "UDP" - Open System: "MELSOFT connecti... More Details >>
- No:22654
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:02
- Category: MELSEC-Q Series
-
How to use PWM output of LCPU built-in I/O
Set the PWM output-on-width and the PWM output cycle, and then execute a dedicated instruction "ICPWM instruction". More Details >>
- No:22757
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
File format that can be saved to a CF card in the FX3U-CF-ADP
CSV file can be saved. More Details >>
- No:24938
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Main Unit , Accessories
-
Switching network between 10BASE-T and 100BASE-TX of the FX3U-ENET-L
It cannot be freely switched. It is automatically switched according to the auto detection function. More Details >>
- No:24964
- Release Date:2019/04/23 07:18
- Category: MELSEC-F Series , Network/Communication