Regarding PDO Mapping Settings
PDO mapping is configured from the CC-Link IE TSN configuration settings. ① Open the CC-Link IE TSN configuration settings from the FX5-CCLGN-MS Basic Set... More Details >>
- No:44475
- Release Date:2024/07/02 19:07
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the MQTT communication function retransmission function
No, there is no function to resend all the data that could not be sent. By setting Retain and QoS from FB, it is possible to resend only the latest message. More Details >>
- No:44368
- Release Date:2024/03/27 16:56
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding FX5-CCLIEF Maximum Link Points
The maximum link points of the FX5-CCLIEF are 384 points each for RX/RY and 1024 points each for RWw/RWr. More Details >>
- No:40020
- Release Date:2023/08/24 14:31
- Category: MELSEC iQ-F Series , Network/Communication
-
Output numbers of the FX programmable controllers
Since they are octal, the number after Y7 is Y10 and after Y77 is Y100. More Details >>
- No:24946
- Release Date:2019/04/18 14:26
- Category: MELSEC-F Series
-
E-mail sending/receiving function of the FX3U-ENET-L
E-mail sending function is supported, but receiving function is not available. More Details >>
- No:24930
- Release Date:2019/04/17 11:39
- Category: MELSEC-F Series , Network/Communication
-
Communication setting methods when the FX3U-232-BD is used
The non-protocol communication can be set by the following two methods: (1) setting parameters using a programming tool, such as GX Works2, or (2) writing da... More Details >>
- No:24773
- Release Date:2019/02/27 15:24
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Refresh timing of bit data and word data in the same CC-Link station
Cyclic data is sometimes separated into new and old data by two words (32 bits) with auto refresh timing. Checking "Block data assurance per station" of the ... More Details >>
- No:23058
- Release Date:2018/09/03 17:31
- Category: Network related products
-
What makes the ERR LED flash in a CC-Link network
A link error has occurred in one of the slave stations in connection.Master station: Check the parameter again.Slave station: Reassess the power supply, the ... More Details >>
- No:23023
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Using a FROM/TO instruction after AJ71UC24 is replaced with QJ71C24N
I/O signals and buffer memory addresses need to be changed but data communications can be conducted using a FROM/TO instruction and X/Y signals. More Details >>
- No:23017
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Writing comments into a programmable controller
Make a space for comments in the parameter setting of the programmable controller with GX Developer.To write the created comments into a programmable control... More Details >>
- No:22962
- Release Date:2018/09/03 17:31
- Category: Engineering Software