Regarding CC-Link IE Field Network Basic Refresh Settings
You can't. Device allocation for refresh settings is sequential only. More Details >>
- No:39306
- Release Date:2023/02/13 16:41
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding GX Works3 Module configuration diagram
It can't be configured. In the module configuration diagram of GX Works3, the configurations that can be created are those excluding FX5-CNV-IFC and FX3 Int... More Details >>
- No:39331
- Release Date:2023/02/14 09:08
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the differences between Latches (1) and (2)
Whether the latch range is set by default is different. ・Latch (1) — Latch range is set by default. This can be changed at any time. ・Latch (2) — No latch ... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Update:2024/08/19 09:54
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Using the email function of FX5-ENET, it is possible to send mail via a mail server. The email function is supported in the following versions. ・Hardware s... More Details >>
- No:40035
- Release Date:2023/08/24 15:40
- Update:2023/08/25 11:34
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding forced ON/OFF function for external input/output
The "Forced ON/OFF function for external input/output" that forces X/Y devices to turn on/off from GX Works3 is supported with the following firmware version... More Details >>
- No:44330
- Release Date:2024/03/20 12:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding automatic transfer of Data Logging Files
Data logging file transfer (FTP server auto transfer) is supported with the following firmware versions. ・FX5U/FX5UC CPU Module Ver. 1.300 or later ・FX5U... More Details >>
- No:44334
- Release Date:2024/03/20 13:30
- Category: MELSEC iQ-F Series , CPU Module
-
The following points are different for the iQ-F series. ・Error History If the FX5 CPU Module is turned off, the error history is cleared. ・Setting detail... More Details >>
- No:44335
- Release Date:2024/03/20 13:21
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding differences between Analog Module and Analog Adapters
FX5-4AD and FX5-4DA are intelligent function Modules. ・Connect to the right side of the CPU Module. ・Control via buffer memory (BFM). ・It also supports ... More Details >>
- No:44347
- Release Date:2024/03/27 15:21
- Category: MELSEC iQ-F Series , Analog
-
Regarding updating the FX5U/FX5UC CPU module to firmware version “1.100 ” or later
To update to firmware version “1.100 ” or higher, you need a product with serial number (S/N) or higher listed below. ・FX5UC-32MT/DS-TS and FX5UC-32MT/DSS-T... More Details >>
- No:44623
- Release Date:2024/11/28 16:14
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding whether ladder monitoring is enabled by the Web server function
You cannot use the ladder monitor with the Web server function. With the Web server function, it is possible to monitor the device value, test the device (w... More Details >>
- No:44873
- Release Date:2025/03/18 10:23
- Category: MELSEC iQ-F Series , CPU Module