QJ71E71-100's compatibility with the automatic cable type (straight or cross) recognizing function
QJ71E71-100 does not support the AutoMDI/MDI-X function (automatic cable type (straight or cross) recognizing feature). More Details >>
- No:22976
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Number of remote registers assigned to a remote I/O station
For "Remote Net(Ver.2 Mode)", the number of remote I/O's remote registers (RWw, RWr) is "0 Point". More Details >>
- No:22973
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Terminating resistors for RS-422 communication of QJ71C24N
The resistance value is 330 ohm, 1/4 W. More Details >>
- No:22965
- Release Date:2018/09/03 17:31
- Update:2018/10/03 15:33
- Category: Network related products
-
Setting for sequentially inputting device comments in GX Works2
Select [Tool]-> [Options]-> [Program Editor] -> [Ladder/SFC] -> [Enter ladder] from the menu, and set [Enter label comment and device comment]... More Details >>
- No:22938
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:54
- Category: Engineering Software
-
MX Component Version 4's compatibility with Visual Studio 2005
Yes. More Details >>
- No:22914
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Developer's compatibility with LJ71E71-100
GX Developer does not support LJ71E71-100. Use GX Works2. More Details >>
- No:22911
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Languages supported by structured projects
Yes. More Details >>
- No:22855
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Usage of UPS (uninterruptible power supply)
No, it cannot be used. More Details >>
- No:22831
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Yes. As a guide, the processing time is shown below.For the logging condition, refer to figure 1 below. - For 16 devices: 2 ms - For 64 devices: 6 ms More Details >>
- No:22829
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:33
- Category: MELSEC-L Series