FAQ


FAQAbout Products

- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
CPU clock setting by SNTP functions via built-in Ethernet port in LCPU
The clock setting of the CPU module is set automatically in accordance with the clock data collected from the time information server (SNTP server) on the LAN. More Details >>
- No:22736
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors.(1) The module that has been specified by a FROM/TO instr... More Details >>
- No:22830
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Operation performed when file registers are read
Checking "Device Memory" does not read file registers. Switch the Target Memory for "PLC Data" to "Standard RAM" and check "File Register" in the Read from P... More Details >>
- No:22835
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Time out error in the communication test of MX Component
The possible causes are as follows. - Incorrect setting with a personal computer or an Ethernet interface module Check the IP address, network number, sta... More Details >>
- No:22934
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:49
- Category: Engineering Software
-
Setting a high-speed timer and a low-speed timer
In the PLC parameter setting of GX Developer, delete the start "200" of the default high-speed timer and input "0". The message indicating that "There is a d... More Details >>
- No:22943
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Difference between networks called CC-Link and those called MELSEC
CC-Link IE, supported by the CC-Link Partner Association, is an open field network standard that integrates networks, from a controller network to field/moti... More Details >>
- No:23013
- Release Date:2018/09/03 17:31
- Category: Network related products
-
MODE switch setting for QJ61BT11N
The MODE switch can set the following modes.- 0 to 4: Online mode- 5 to 9: Line test mode- A to E: Hardware test modeEach mode in ascending order of set valu... More Details >>
- No:23025
- Release Date:2018/09/03 17:31
- Category: Network related products
-
How to check the scan time (MELSEC-F series)
The present scan time is stored in D8010. Monitor the valueusing a programming tool such as GX Works2 and GX Developer. More Details >>
- No:24685
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Setting day of the week when using the TWR instruction (FX3 series)
Day of week is automatically set. When data written to the data register for storing day-of-the-week data is within the setting range (K = 0 to 6), the day ... More Details >>
- No:24777
- Release Date:2019/02/27 15:57
- Category: MELSEC-F Series , Main Unit
-
Replacement of the fuse in the FX programmable controller
Customers cannot replace the fuse. For the replacement, please consult your local Mitsubishi representative. More Details >>
- No:24909
- Release Date:2019/04/15 11:30
- Category: MELSEC-F Series , Main Unit