FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Parameter setting of the FX3U-16CCL-M
The parameters can be set by using network parameters of GX Works2 (Ver1.73B or later). (FX3U/3UC: Ver3.10 or later) More Details >>
- No:25013
- Release Date:2019/04/23 11:16
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding CC-Link IE field network support of FX5 CPU module built-in Ethernet
The built-in Ethernet on the FX5 CPU module does not support CC-Link IE field networks. If you use a CC-Link IE field network, add an FX5-CCLIEF. *The FX5-... More Details >>
- No:44877
- Release Date:2025/03/18 10:30
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Ver.3.10 or later is applicable. (GX Works2 with Ver.1.73B or later is applicable.) The version of the main unit can be checked with the last three digits of... More Details >>
- No:24918
- Release Date:2019/04/17 11:40
- Category: MELSEC-F Series , Main Unit
-
Regarding checking latch settings
You can find it in the Advanced Settings section of GX Works3. Use the following procedure to display the Device (High Speed) settings. From the GX Wor... More Details >>
- No:44364
- Release Date:2024/03/27 16:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding communication supported by built-in RS-485 port
N:N Network, Parallel Link, MC protocol, Non-protocol communication, MELSOFT connection, MODBUS RTU, and Predefined protocol support are available. More Details >>
- No:22322
- Release Date:2018/08/30 13:55
- Update:2022/12/22 10:16
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Automatically assigned devices in GX Works2
Yes.Beginning with the device in the "Device/Label Automatic-Assign Setting" window, devices are assigned in descending order (from the greatest device numbe... More Details >>
- No:22846
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Regarding the differences between Latches (1) and (2)
Whether the latch range is set by default is different. ・Latch (1) — Latch range is set by default. This can be changed at any time. ・Latch (2) — No latch ... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
- Update:2024/08/19 09:54
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the processing specification of the basic operation instruction(LD).
The execution time of the basic opeartion instruction (LD) of the FX5U/FX5UC/FX5UJ CPU module is 34 ns. *For firmware Ver.1.100 or above, this specification ... More Details >>
- No:22287
- Release Date:2018/08/30 13:55
- Update:2023/07/03 11:56
- Category: MELSEC iQ-F Series , CPU Module
841-850 of Total 1023