Regarding use of the FTP Server Auto Transfer Function with Other Functions
Be careful when using the FTP server auto transfer function in combination with the following functions. ・FTP client (FTPPUT instruction) The function exe... More Details >>
- No:44336
- Release Date:2024/03/20 13:28
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Input Interrupt Delay
The following versions support the input interrupt delay function and can delay the start of execution. ・FX5U/FX5UC Ver. 1.290 or later ・FX5UJ Ver. 1.050 o... More Details >>
- No:40037
- Release Date:2023/08/24 15:43
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding nesting contacts displayed on bus by master control instructions
It is not possible. More Details >>
- No:39361
- Release Date:2023/02/15 13:04
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Input numbers of the FX programmable controllers
Since they are octal, the number after X7 is X10 and after X77 is X100. More Details >>
- No:25000
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Target address change during the positioning operation in the FX3U-1PG
Yes, it is possible. Set a new value for the target address to the target address change value (BFM#54, #53) during the positioning operation. * The targ... More Details >>
- No:24986
- Release Date:2019/04/23 07:22
- Category: MELSEC-F Series , Positioning Control
-
The heater disconnection detection function monitors the heater current on the transistor output. If no current flows when the transistor is ON, it is consi... More Details >>
- No:22773
- Release Date:2018/09/03 17:30
- Update:2018/09/22 10:58
- Category: MELSEC-L Series
-
Opening a project in an old version of GX Developer
Products earlier than version 8.58L do not support a project in which the following parameters are set. All the parameters are set to their default values be... More Details >>
- No:22666
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:53
- Category: MELSEC-Q Series
-
Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Setting of the FX3U-ENET-ADP Ethernet communication special adapter
GX Works2 with Ver. 1.90U or later can be used for the setting of the FX3U-ENET-ADP. More Details >>
- No:24875
- Release Date:2019/04/15 08:06
- Category: MELSEC-F Series , Network/Communication
-
Regarding 2-axis synchronous control
FX5-40SSC-S(Simple motion) or FX5-80SSC-S(Simple motion), FX5-40SSC-G (CC-Link IE TSN Motion) or FX5-80SSC-G (CC-Link IE TSN Motion) supports the synchrous c... More Details >>
- No:22325
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:31
- Category: MELSEC iQ-F Series , Motion/Positioning