FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>
- No:22650
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:47
- Category: MELSEC-Q Series
-
Simple PLC communication function
This function allows data communications between specified devices at the specified timing, using the built-in Ethernet. Device data such as production data ... More Details >>
- No:22737
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to check the scan time (MELSEC-F series)
The present scan time is stored in D8010. Monitor the valueusing a programming tool such as GX Works2 and GX Developer. More Details >>
- No:24685
- Release Date:2019/02/22 11:40
- Update:2019/02/22 15:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
The station number setting is not required for non-protocol communication. More Details >>
- No:24948
- Release Date:2019/04/18 14:27
- Category: MELSEC-F Series , Main Unit , Network/Communication
-
Regarding simultaneous access to Web Server function
The Web server function allows you to log in from up to four devices at the same time. You can't log in from the fifth machine. More Details >>
- No:39330
- Release Date:2023/02/14 09:06
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Behavior of special relay in simulation
The constant scan initial value in the simulation function is 100ms. Thus, the value of SM410(0.1sec. clock) is OFF in each scan. To turn ON/OFF SM410, set ... More Details >>
- No:22521
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:23
- Category: MELSEC-Q Series
-
Inputting device comments in GX Works2
Select [Tool] -> [Options] -> [Program Editor] -> "Ladder/SFC"-> "Comment" and change "Reference/Reflection Target for Device Comment" from "Glob... More Details >>
- No:22559
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Reception data read request signal of QJ71C24N not turn ON
The default receive complete code is CR+LF (0DH, 0AH). The default received data count is 511 words. Hence, at their defaults, Reception data read request si... More Details >>
- No:22984
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:22
- Category: Network related products
-
Receiving back (echoing back) the same data sent from QJ71C24N
When data is sent from the RS-422/485 interface through RS-485 (2-wire type) communication and the same data comes back to RDA or RDB, we call it echo back. ... More Details >>
- No:23000
- Release Date:2018/09/03 17:31
- Update:2018/09/25 17:44
- Category: Network related products
-
To establish communications between the programmable controller and GX Developer, clear the communication setting. (The communication setting register value ... More Details >>
- No:24876
- Release Date:2019/04/15 08:07
- Category: MELSEC-F Series , Engineering Software , Main Unit
901-910 of Total 1023