How to check automatically assigned devices in GX Works2
Click the local label to be checked and select "Cross Reference" from the right-click menu to check the devices. More Details >>
- No:22700
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Models of extended SRAM cassettes that can be used with MELSEC iQ-R series CPU modules
You can use "NZ2MC-1MBS", "NZ2MC-2MBS", "NZ2MC-4MBS", "NZ2MC-8MBS", "NZ2MC-16MBS",and "NZ2MC-8MBSE". You cannot use extended SRAM cassettes for the high-spe... More Details >>
- No:22468
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:36
- Category: MELSEC iQ-R Series
-
Assignment of remote input device and remote output device of FX3U-16CCL-M
The remote input device and the remote output device cannot be assigned in network parameters. To assign them, create a program for updating data. For de... More Details >>
- No:24792
- Release Date:2019/02/28 09:08
- Category: MELSEC-F Series , Engineering Software , Network/Communication
-
Can I open a program created with GX Developer in GX Works2?
Yes, you can. Select [Project]-> [Import file]-> [Import from xxxx format file] and specify a project file. More Details >>
- No:22957
- Release Date:2018/09/03 17:31
- Update:2018/09/25 12:13
- Category: Engineering Software
-
Specifying the number of digits in the Structured Text
For actual bit devices, the number of digits can be specified. For labels, the number of digits cannot be specified. More Details >>
- No:22891
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
MX Component Version 4's compatibility with the L series CPU
MX Component Version 4 supports the L series CPU. More Details >>
- No:22867
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Cable length to connect to built-in Ethernet port in LCPU
The maximum length between a hub and a node is 100 m. The max. length connectable to a hub is 200m.When repeater hubs are used in cascade connection, the max... More Details >>
- No:22781
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
How to display the parameter setting window for a programmable controller with GX Works3
You can display the setting window from a module configuration diagram or system parameters. <Displaying the setting window from a module configuration... More Details >>
- No:22498
- Release Date:2018/09/03 17:28
- Update:2018/09/20 12:10
- Category: MELSEC iQ-R Series
-
How to use the database function of the MELSEC iQ-R series
The database function manages tabular data including product information and production information as a database in a programmable controller. <... More Details >>
- No:22476
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:44
- Category: MELSEC iQ-R Series
901-910 of Total 1010