Required setting for the display of hidden comments
Device comments can be displayed in the ladder editor and Zoom editor windows. Select [View] -> [Comment] from the menu to display the comments. More Details >>
- No:22875
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:40
- Category: Engineering Software
-
Indication accuracy - Ambient temperature: 25+/-5 degrees Celsius Full scale x (+/-0.3%) - Ambient temperature: 0 to 55degrees Celsius Full scale x (+/-0... More Details >>
- No:22820
- Release Date:2018/09/03 17:30
- Update:2018/09/26 16:51
- Category: MELSEC-L Series
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of END cover with the branch module and extension module
Use an END cover applicable to the following. - The L6EC whose serial number (first six digits) is "*****2" or later- END cover with ERR terminal (optional i... More Details >>
- No:22815
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
The minimum input response times are different. The minimum input response time is 100 microseconds for standard inputs, and 10 microseconds for high-speed i... More Details >>
- No:22804
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Method to prevent the BAT.LED from turning on
To prevent an LED from turning on when an error occurs, set 0 to the relevant factor number setting area (4 bits for each) in SD207 to SD209. To disable the ... More Details >>
- No:22754
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Use of a commercial SD memory card in L series logging function
Yes. Recommended products are listed in the technical bulletin FA-A-0078. More Details >>
- No:22753
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:25
- Category: MELSEC-L Series
-
LCPU built-in Ethernet port setting when using the simple PLC communication function
The following settings are required for the "Open Setting" for the number of connected external devices.- Protocol: "UDP"- Open System: "MELSOFT connection" More Details >>
- No:22739
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Detecting the connection between a built-in Ethernet port QCPU and hub
You can check the connection to the hub with bit 10 of the special register SD1288. When bit 10 of the SD1288 is on, the QCPU is in connection with the hub. More Details >>
- No:22712
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Print settings of the device list in GX Works2
When [Display Option] -> [Used devices] -> [Contact] and [Coil] are selected in the Device List window, devices used are not displayed. More Details >>
- No:22661
- Release Date:2018/09/03 17:29
- Update:2018/09/21 12:18
- Category: MELSEC-Q Series