The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>
- No:22650
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:47
- Category: MELSEC-Q Series
-
Differences between GX Works3 and GX Works2
GX Works3 provides various intuitive features such as graphic-based system configuration and an extensive module library (module label/FB) as standard. You... More Details >>
- No:22489
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:43
- Category: MELSEC iQ-R Series
-
Error code "2200" in the universal model QCPU
The error code "2200" is "MISSING PARA.". The cause of the error is that a parameter file does not exist in all drives where parameters will be valid.As a re... More Details >>
- No:22614
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Yes. A USB driver needs to be installed.For the installation procedure, refer to the following manual. - GX Developer Version 8 Operating Manual (Startup) More Details >>
- No:22504
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:10
- Category: MELSEC-Q Series
-
How to check devices assigned to labels of GX Works3
GX Works3 and the MELSEC iQ-R series do not use actual devices as automatic assignment devices of local labels. The local labels use "label areas" in the "d... More Details >>
- No:22486
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:30
- Category: MELSEC iQ-R Series
-
Displaying comments in GX Works2
Select [View] -> [Comment] from the menu to display comments. You can display local comments with the following procedure. (1) Select [Tool] -> [Op... More Details >>
- No:22941
- Release Date:2018/09/03 17:30
- Update:2018/09/25 09:58
- Category: Engineering Software
-
Language selection function of GX Works2
You can select the language to be used in project data (device comments, statements, notes, etc.).With this function, you can select the language to be used ... More Details >>
- No:22936
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
GX Works2's USB driver installation procedure
The USB driver is not installed.The driver needs to be separately installed before the first connection to a CPU module. More Details >>
- No:22507
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Deleting all programs and data from the memory
Data can be cleared from GX Developer or GX Works2. [Online]→Select all [PLC memory], [Data device], and [Bit device.] on the Clear PLC memory window, and e... More Details >>
- No:22269
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
An error (error code: F1028) occurs when compilation is executed in GX Works2.
You have used the device set as the automatic assignment device for labels in the program. Change the device with the one out of the range or change the auto... More Details >>
- No:22954
- Release Date:2018/09/03 17:30
- Category: Engineering Software