FAQ within [ Programmable Controllers MELSEC ]
-
Battery replacement for High-Performance model QCPU
The contents of the program memory, the standard RAM, and latch devices are not erased if the battery replacement is completed within three minutes, which is... More Details >>
- No:22568
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Recommended cables for MODBUS(R) interface module QJ71MB91
The RS-232 cable should meet RS-232 standards and not exceed 15 m in length.The RS-422/485 cable should meet specifications described in the following manual... More Details >>
- No:22566
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Interrupt program priority setting of MELSEC iQ-R series
You can set interrupt priorities 5 to 7 for interrupt pointers (I0 to I15, I50 to I1023) from the module. You cannot change the priorities of interrupt poin... More Details >>
- No:22482
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:05
- Category: MELSEC iQ-R Series
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the change of settings for reserved station (master station) of FX5-CCLGN-MS
FX5-CCLGN-MS allows the master station to change the reserved station setting with parameters, but the setting can not be changed by program. Note that link... More Details >>
- No:39275
- Release Date:2023/01/12 16:46
- Category: MELSEC iQ-F Series , Network/Communication
-
Refresh timing of bit data and word data in the same CC-Link station
Cyclic data is sometimes separated into new and old data by two words (32 bits) with auto refresh timing. Checking "Block data assurance per station" of the ... More Details >>
- No:23058
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Precaution about MELSECNET/H connection (2)
- Set the network module mounted in system A to station number 0 (multiplexed remote master station). Set the network module mounted in system B to any sta... More Details >>
- No:23054
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:00
- Category: Network related products
-
About network parameters when building MELSECNET/10 with Q02HCPU-A
Q02(H)CPU-A is the AnUCPU equivalent. When establishing a MELSECNET/10 network, set the refresh parameter with which SB/SW data is transferred to "Y/D" or o... More Details >>
- No:23005
- Release Date:2018/09/03 17:31
- Update:2018/09/26 14:42
- Category: Network related products
-
PLC parameter setting for QJ61BT11N
If the Network Parameter is used, CC-Link communication does not need the Select setting in the I/O assignment setting of the PLC parameter.If the parameter ... More Details >>
- No:23002
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link master modules' start I/O No. and refresh devices RX/RY
The I/O numbers used for I/O modules and intelligent function modules cannot be used as refresh targets for RX/RY. Use the I/O numbers greater than those use... More Details >>
- No:22997
- Release Date:2018/09/03 17:31
- Category: Network related products