Connected position of branch module and extension module
The position to connect the branch module and extension module is as follows. More Details >>
- No:22814
- Release Date:2018/09/03 17:30
- Update:2018/09/22 15:27
- Category: MELSEC-L Series
-
SNTP communication error in built-in Ethernet port LCPU
The error does not affect the CPU time. The CPU time is not set when a communication error occurs. More Details >>
- No:22783
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
LCPU internal clock synchronization
Use the time setting function to synchronize the internal clock. More Details >>
- No:22755
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Configuration of simple PLC communication function using LCPU
At least one L series CPU is necessary when using the simple PLC communication function. More Details >>
- No:22747
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to specify intelligent function module devices
For "U**", set the first two digits of the start I/O number of an intelligent function module in three-digit representation.Example) For X/Y1F0, set "U1F". More Details >>
- No:22704
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Whether or not device indirect specifications in structured ladder programs are allowed
Indirect specifications with "@" cannot be used in structured ladder programs and the Structured Text. Use indirect specifications in a ladder language program. More Details >>
- No:22697
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Update timing of QD75 current feed value and machine feed value
The values are updated at the timing described below.- Current feed value: 1.8 ms- Machine feed value: 56.8 ms More Details >>
- No:22689
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Execution in a multi task environment
The QBF_Open ( ) function or mdOpen ( ) function is required for every task. Do not share the PATH acquired using an Open function with other tasks.Also, exe... More Details >>
- No:22678
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to read comments in the standard ROM with GX Works2
Select [Target Memory] -> [Standard ROM] in the Read from PLC window. More Details >>
- No:22673
- Release Date:2018/09/03 17:29
- Update:2018/09/21 14:05
- Category: MELSEC-Q Series
981-990 of Total 1023